Canon BJC-1000 Printer
General
Cartridge 
- BC-02 - Black Ink & Integral Print Head
 - BC-05 - Colour Ink & Integral Print Head
 - BC-06 - Photo Ink & Integral Print Head
 - BC-09f - Fluorescent Ink & Integral Print Head
  
Serial Number 
Location - Cream coloured label on the rear of the printer, centre back of sheet feed. 
 Error Codes
The BJC-1000 does not beep or have any LEDs to indicate errors.  All errors are reported via the computer with error messages. 
| Error Condition | Error Indication on Computer | Error Code | Possible Solution |  
| Paper Feed | The Printer is out of paper |   | Add Paper |  
| Paper Jam | A paper jam has occurred |   | Remove any paper jammed |  
| Home Position | An error that possibly requires a service call has occurred | 5000 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |  
| Carriage Control | An error that possibly requires a service call has occurred | 5100 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |  
| Temperature Sensor | An error that possibly requires a service call has occurred | 5400 | Try unplugging the printer for 30 seconds, if not requires a service. |  
| No Cartridge Error | An error that possibly requires a service call has occurred | 5600 | Try reinstalling Cartridge or replacing the cartridge |  
| Cleaning Error | An error that possibly requires a service call has occurred | 5C00 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |  
| EEPROM | An error that possibly requires a service call has occurred | 6800 | Try unplugging the printer for 30 seconds, if not requires a service. |  
| Waste Full | An error that possibly requires a service call has occurred | None | Needs Service |  
 
Waste Error Reset 
1: Remove Cartridge 
2: Unplug the AC Power Cord 
3: Hold down the RESUME button 
4: Release RESUME after plugging in the AC Power cord.  
5: Press the RESUME once within 5 seconds and release the RESUME .  
6: Press and HOLD RESUME for two seconds or more and release it.  
7: Press and HOLD RESUME for two seconds or more and release it.  
8: Unplug AC Power Cord to set data. 
 
 
 
 
 |